Common problems and solutions for spray scrubber

Jul 14, 2024 Leave a message

Why does the filler in the spray tower run to the side and how to deal with it?

A: Because the fan air volume is too large, the size of the spray tower does not match the fan air volume, causing the filler to run to one side. It is necessary to smooth the packing first, and then lay a layer of less than 5 cm diameter screen on the packing.

 

Why spray tower nozzle often clogged, how to clean?

A: The reason for the blockage of the spray tower nozzle is whether the filter plate of the water tank is complete. When cleaning the debris in the water tank, do not take out the filter plate, and sweep the filter plate up and down with a broom.

The cleaning method is to first remove the window screw, take offer the transparent plate, put on protective clothing and enter into the spray tower, remove the nozzle to clean up, and then install the clean nozzle back. People come out and smooth the packing inside the spray tower, and then put the window glue pad in place, and the transparent plate can be locked with screws.

 

Spray tower pump normal operation, nozzle water is very small, why?

A: Check whether the water inlet at the bottom of the spray tower pump is dirty and blocked, if so, please clean it up in time. Detect whether the water pump wheel is blocked by impurities. Check whether the nozzle is blocked, remove the window to check the nozzle spray, clean and maintain in time.

 